Custom Fan Filters for clean rooms - Semiconductor & Pharmaceutical
HOME | ABOUT US | CONTACT US
 

LINKS IN THE TEXT OF THIS PAGE ON OLD SITE RESULT IN PAGE/FILE NOT FOUND

Standard and Custom FFU's

The Standard Unit Features a 99.9995% @ 0.1 Micron Minimum Efficiency Glass ULPA Filter

A fully tested and certified, silicone free, microfiber glass ULPA filter with 2” pleat pack depth and 0.68” WC pressure drop at 100 FPM filter face velocity has a minimum efficiency of 99.9995% on 0.10 Micron particles. It comes with an integral flattened metal expanded facescreen, painted white and located on the downstream side.

AAF Glass ULPA pressure and efficiency curves 404 (pdf)

Note: One of the most important features of the FFU is the proper selection of the media for the application (E.G. must use PTFE for 300 mm applications).

Options

99.99% @ 0.3 Micron HEPA Filter
For those conscious of initial cost and not requiring a filter rated at 0.1 micron a 99.99% @ 0.3 micron minimum efficiency, silicone free, micro fiber glass HEPA filter with 2” pleat pack can be substituted for the glass ULPA filter.

PIC OF HEPA filter media efficiency and pressure drop curves 404  (pdf)

Lower Pressure Drop Filter
For those applications where a lower initial pressure drop, and/or higher CFM output is desired, pleat pack heights of 3” or 4” can be substituted for the standard 2”.

PIC of pressure drop curves for 3” and 4” glass 404  (pdf)

PTFE Filter/300 mm Applications

For applications where the FFU will provide clean air to a 300 mm semiconductor application the Sematech I300I Factory Guideline Compliance: Factory Maturity Assessment (FIMA) for 300 mm.

AAF MEGACEL LIT 404  (pdf)

Sematech's, I300I Factory Guideline Compliance: Factory Integration Maturity Assessment (FIMA) for 300 mm Production Equipment 404  (pdf) (full document is available by request from TES-Clean Air Systems)

No Facescreen on the Filter  
For those applications where the filter can have nothing below the surface of the filter media, the filter is provided without a face screen. (We generally do not recommend this and only conditionally recommend it when PTFE media is used).
Perforsted Stainless Steel Facescreen  
For those applications where the filter can have nothing below the surface of the filter media, the filter is provided without a face screen. (We generally do not recommend this and only conditionally recommend it when PTFE media is used).

LINKED IMAGE ON OLD SITE WAS WRONG
Filter Has an Aerosol Test Port  
For those applications requiring an aerosol leak test a test port can be supplied in the HEPA or ULPA filter in a center board in the filter.

 

 
41 East Airway Blvd. Livermore, CA 94551 | Phone: (510) 656-5333 | Fax: (510) 656-5335